Install NX25 Bypass Valve Kit in 14 steps.
WARNING: Relieve pump pressure and disconnect power before starting
Installation of Fill-Rite's NX25 Series Bypass Valve Kit
Accessing the Bypass Valve Assembly, Inlet Screen, and Gasket
WARNING: Wear safety glasses while working with bypass valve
- Remove any accessories on outlet of pump
- Remove pump from bung adapter
- Use wrench to loosen fasteners
- Remove gasket and screen from bung adapter, wipe away any remaining debris
- Push bypass spring and cap down, rotate cap 90 degrees to unlock valve
- Use 4" object in inlet to push bypass valve into place, hold bypass valve in place
- Use 4" object in outlet to grab bypass valve cap
- Push bypass cap down and rotate 90 degrees
- Remove pieces
Replacing the Bypass Valve Assembly, Inlet Screen, and Gasket
- Insert bypass spring tip-side first into opening, hold in place with blunt object
- Drop spring through outlet onto the bypass poppet
- Place bypass cap over spring in pump outlet
- Push bypass cap down over locking tab and rotate bypass cap 90 degrees
Replacing Inlet Screen and Gasket
- Place inlet screen in indentation, ensure properly seated
- Place gasket on bung adapter
- Mount pump on bung adapter, secure with 4 fasteners