Install FR900 Digital Meter Kit in 16 steps.
Directions to Install FR900 Digital Meter Full Rebuild Kit
Disassembly of Meter Housing
- Flip meter over
- Remove (8) fasteners from meter body
- Remove gasket
- Remove (4) fasteners and chamber assembly
- Use retaining ring pliers to remove retaining ring
- Remove magnetic driver and spring
Install Magnetic Driver
- Place new gasket onto meter cover
- Place driver spring onto shaft
- Place magnetic driver onto shaft
- Push the driver and spring down, secure with retaining ring
Installing Chamber Assembly
- Install new chamber assembly with opening facing meter inlet
- Secure in place with (4) fasteners
Reassembly of the Meter
- Place meter housing onto meter cover
- Secure (8) fasteners, tighten to at least 100 in-lb
Replacing Flange Gaskets
- Remove flanges, discard old gaskets
- Place new gaskets in indentations, reinstall flanges