How to install FR900 Digital Meter Kit

Install FR900 Digital Meter Kit in 16 steps.

Directions to Install FR900 Digital Meter Full Rebuild Kit

Disassembly of Meter Housing

  1. Flip meter over
  2. Remove (8) fasteners from meter body
  3. Remove gasket
  4. Remove (4) fasteners and chamber assembly
  5. Use retaining ring pliers to remove retaining ring
  6. Remove magnetic driver and spring

Install Magnetic Driver

  1. Place new gasket onto meter cover
  2. Place driver spring onto shaft
  3. Place magnetic driver onto shaft
  4. Push the driver and spring down, secure with retaining ring

Installing Chamber Assembly

  1. Install new chamber assembly with opening facing meter inlet
  2. Secure in place with (4) fasteners

Reassembly of the Meter

  1. Place meter housing onto meter cover
  2. Secure (8) fasteners, tighten to at least 100 in-lb

Replacing Flange Gaskets

  1. Remove flanges, discard old gaskets
  2. Place new gaskets in indentations, reinstall flanges